Slow Dental Turbine Handpiece, Dental Air Rotor Handpiece

Product categories

Slow Dental Turbine Handpiece , Midwest Dental Air Rotor Handpiece Inner Channel

Slow Dental Turbine Handpiece , Midwest Dental Air Rotor Handpiece Inner Channel

Compare

Description

Slow Dental Turbine Handpiece , Midwest Dental Air Rotor Handpiece Inner Channel

Detailed Product Description
Air Pressure: 0.30-0.35Mpa Spray: Inner Channel
Bur Size: D2.345-2.355mm/D1.595-1.600mm Speed: ≥18.000R.P.M
Ratio: 1:1 Chuck Type: Push Button
High Light:

air turbine handpiece

,

air powered dental drill

 

Inner Channel Dental Turbine Handpiece Low Speed Handpiece Push Button Type

 

Product Description:

Low Speed handpiece set

Inner water spray

Contra angle, straight handpiece, air motor

 

Specification:

– E-type connector

– Precise technology, Steady, no vibration while revolving, offering a steady operation.

– Suitable for any E-type handpiece accords with ISO standard

– 135°C Autoclavable, suitable for both steam and chemical autoclave.

 

Technical:

Ratio: 1:1Ratio

Air pressure: 0.30-0.35Mpa

Color tem.3500K–4000K

Speed: ≥18.000R.P.M

Chuck Style: push button style

Bur size: D2.345-2.355mm/D1.595-1.600mm

Noise: ≤70db

Water Spray: Inner channel water spray

Name Inner channel low speed dental handpiece
Noise ≤70db
Color tem 3500K–4000K
Speed: ≥18.000R.P.M

Application:
Professionally used by dentists as oral operative surgery tools.

Notes & Cautions
1. Notes before operation
The product is available for dental inner spray air/electric motor in accordance with E type connector only.
Only to be used by a qualified dental practitioner.
Before using, please check burs and function of the chuck at outside of oral cavity of patients, if loose, too much vibration, irregular noise and too much heating up etc, please dot not carry on.
Avoiding crash and drop.
Forbidding disassembling or conversion.
It shall be sterilized before handpiece is used at the first time and after treatment.
Do not insert or remove bur while the bur is in motion.
Please use standard bur or drill.
Please do not exceed the max rotation speed of the bur or drill.
Please keep the bur or drill be clean. Any other foreign particles get inside, it may cause vibration, weak chucking power or other abnormalities.

 

2. Notes in operation
Please do not operate without spray.
Please do not let the motor speed exceed the max diving motor speed, otherwise will accelerate mechanical wear or damage the handpiece.
Please do not operate without bur or drill.
Please do not push the back cap while the handpiece is in motion, that will cause the handpiece damage
or the bur brust out.
3. Notes after operation
The handpiece is forbidden to put into digital ultrasonic cleaner, otherwise will damage the generator and LED light.
Please cleaning, lubricating and autoclaving after treatment. Otherwise the blood will make the cartridge corrosion.
The handpiece will heat up if lack lubricating.
Please do not use the acid solution to scrub, inject or soak the handpiece.
Please check the function before long time not use.