  • Small in volume、light in weight and convenient in carrying
  • With SpO2 value and pulse rate value of storage, the storage data can be uploaded to computers
  • The littium battery is rechargable,the screen lightness is changeable,alam function
  • 24 hours data storage.Can be connected to the computer through USB Cable
  • 160*128 TFT Color display.The SPO2 and pulse rate data can be tested accurately.
Qty:
Compare

Description

Contec CMS60C Handheld Pulse Oximeter 

Introduction:

The CMS60C Pulse Oximeter adopts Photoelectric Oxyhemoglobin Inspection Technology in accordance with Capacity Pulse Scanning & Recording Technology, which can be used to measure human oxygen saturation and pulse rate through finger. The device is suitable for being used in hospital, oxygen bar, community healthcare and physical care in sports, etc. (It can be used before or after exercise, but not recommended to use during exercising).

Contec CMS 60C Handheld Pulse Oximeter is designed to determine the SpO2 (blood oxygen saturation levels) and pulse rate. It comes with a real-time alarm function and is suitable for family, hospital, community medical treatment, and sports health care. Moreover, it is suitable for both continuous monitoring and spot check.

Contec CMS-60C Handheld Pulse Oximeter Features:

  • Function switch to activate measurement and turn off the power
  • function key for menu setting
  • Free software to upload and analyze up to 24 hours of data at a time
  • Dual direction display with three adjustable brightness levels
  • 4 parameters readings (SpO2, PR, Bar graph, Pulse waveform)
  • Alarms (auditory and visual) when pulse rate or SpO2 falls below preset levels
  • Pulse sound function
  • Suitable for adult, pediatric and neonatal, an adult probe is included
  • FDA 510K approved

Contec CMS-60C Handheld Pulse Oximeter Specifications:

  • SpO2 Range: 35%-99%
  • Resolution :±1%
  • Accuracy: ±2% (70%~99%)<70%, unspecified
  • Pulse Rate Range:30bpm-250bpm
  • Resolution:1bpm
  • Accuracy: ±2bpm or ±2% (select larger)
  • One rechargeable lithium battery
  • Size:87*45*22mm
  • Display Type:1.8′ 65K Colour TFT
  • Parameter: SpO2 (2-digit), PR (3-digit), bar graph, Pleth waveform
  • Adjustable brightness level
  • 1-year limited manufacturer warranty

In the Box

  • 1 x CMS-60C Unit
  • 1 x Child Oximeter Probe
  • 1 x DC Power Adapter Plug
  • 1 x USB Connector Cord
  • 1 x Instruction Manual

CMS60D software download (SpO2-Assistant-V3.1Setup)

 

Continuous Monitoring

my img

Rechargeable

my img

Backlit Display

my img

Specification

Product Parameters
Product feature : Data storage function, stored data can be uploaded to computer
SpO2 Measuring Range : 0%~100% (resolution is 1%)
Accuracy : 70%~100%: ±2% ,Below 70% unspecified, ±2bpm or ±2% (whichever is greater)
PR Measuring Range : 30bpm~250bpm, (the resolution is 1bpm)
Measurement Performance in Weak Filling Condition : SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2bpm or ±2% (whichever is greater).
Resistance to surrounding light : The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%. Voltage: DC 3.6V~4.2V
Characteristics : Small in volume, light in weight and convenient in carrying Easy to operate, low power consumption Operation menu for function settings SpO2 value display Pulse rate value display, bar graph display Pulse waveform display
Memory function : record 1000 groups of SpO2 data, 224-day pedometer data
Battery working hour: 26 hours in theoretical
Battery service life: no less than 500 times of charge and discharge
Safety type: Internally powered equipment, Type BF applied part

 

Performance:
Display mode: 1.77″ TFT color screen
Screen resolution: 128*160
SpO2 measuring range: 0%~100% (resolution is 1%)
Accuracy: 70%~100%: ±2%, Below 70% unspecified.
PR measuring range: 30bpm~250bpm (resolution is 1bpm)
Accuracy: ±2bpm or ±2% (whichever is greater)
Measurement performance in weak filling condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2bpm or ±2% (whichever is greater).
Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
Voltage: DC 3.6V~4.2V
Power supply: 3.7V rechargeable lithium battery × 1
Battery working hour: 26 hours in theoretical
Battery service life: no less than 500 times of charge and discharge
Safety type: Internally powered equipment, Type BF applied part